dc.contributor.author |
Pilau, Felipe Gustavo |
|
dc.contributor.author |
Angelocci, Luiz Roberto |
|
dc.date.accessioned |
2018-07-05T11:43:54Z |
|
dc.date.available |
2018-07-05T11:43:54Z |
|
dc.date.issued |
2014-07 |
|
dc.identifier.citation |
PILAU, F. G.; ANGELOCCI, L. R. Balanço de radiação de copas de cafeeiros em renques e suas relações com radiação solar global e saldo de radiação de gramado. Bragantia, Campinas, v. 73, n. 3, p. 335-344, Jul./Set. 2014. |
pt_BR |
dc.identifier.issn |
1678-4499 |
|
dc.identifier.uri |
http://dx.doi.org/10.1590/1678-4499.0164 |
pt_BR |
dc.identifier.uri |
http://www.sbicafe.ufv.br/handle/123456789/9999 |
|
dc.description.abstract |
Devido à importância da quantificação da radiação solar interceptada e absorvida por plantas foram realizadas medidas do saldo de radiação (Rnc) de copas em um trecho de renque de cafeeiros, analisando-se o efeito de diferentes áreas foliares no renque e correlacionando-os com dados de radiação solar global (Qg) e saldo de radiação de gramado (Rn). Para a mensuração nos cafeeiros foi utilizado um sistema de integração espaço-temporal com saldo-radiômetros móveis. Os resultados evidenciam uma relação direta porém não proporcional entre Rnc e área foliar das plantas. As relações de Rnc com Qg são específicas para cada área foliar. Os dados não sustentam a hipótese de que o saldo de radiação normalizado por unidade de área foliar seja uma função linear do saldo de radiação de gramado. |
pt_BR |
dc.description.abstract |
Intercepted solar radiation (ISR) is important for plant growth, development and energy fluxes. We used a mobile device carrying on eight net radiometers encompassing coffee plants aligned in hedgerows to measure Rnc. Measures of radiation balance over several coffee hedgerows (Rnc) were taken in order to analyze the effect of leaf area (LA) on ISR as well as its relationship with solar radiation (Qg) and grass net radiation (Rn). Results showed a direct relationship between LA, Rnc and Qg. However, these relations were not linear, which leads us to refute the hypothesis that the normalized Rnc in terms of leaf area would be a linear function of the grass net radiation. |
pt_BR |
dc.format |
pdf |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Instituto Agronômico (IAC) |
pt_BR |
dc.relation.ispartofseries |
Bragantia;v. 73, n. 3, p.335-344, 2014 |
|
dc.rights |
Open Access |
pt_BR |
dc.subject |
Saldo de radiação |
pt_BR |
dc.subject |
Área foliar |
pt_BR |
dc.subject |
Variáveis meteorológicas |
pt_BR |
dc.subject |
Coffea arabica L. |
pt_BR |
dc.subject.classification |
Cafeicultura::Agroclimatologia e fisiologia |
pt_BR |
dc.title |
Balanço de radiação de copas de cafeeiros em renques e suas relações com radiação solar global e saldo de radiação de gramado |
pt_BR |
dc.title |
Radiation balance of coffee tree tops in hedgerows and its relations with global solar and grass net radiations |
pt_BR |
dc.type |
Artigo |
pt_BR |