SBICafé
Biblioteca do Café

Estimativa da transpiração em cafeeiros utilizando sensores de dissipação térmica

Show simple item record

dc.contributor.advisor Silva, Tonny José Araújo da
dc.contributor.author Pimentel, Jussálvia da Silva
dc.date.accessioned 2019-06-12T13:27:37Z
dc.date.available 2019-06-12T13:27:37Z
dc.date.issued 2008-02
dc.identifier.citation PIMENTEL, J. S. Estimativa da transpiração em cafeeiros utilizando sensores de dissipação térmica. 2008. 71 f. Dissertação (Mestrado em Engenharia Agrícola) - Universidade Federal Rural de Pernambuco, Recife. 2008. pt_BR
dc.identifier.uri http://www.sbicafe.ufv.br/handle/123456789/11446
dc.description Dissertação de mestrado defendida na Universidade Federal Rural de Pernambuco. pt_BR
dc.description.abstract O aumento da produtividade com o uso da irrigação pode ser conseguida por melhor eficiência e precisão do uso da técnica no campo. Alguns métodos são capazes de determinar diretamente a quantidade de água consumida por uma planta, entre eles, há o ‘”método de dissipação de calor" ou método de Granier. Esse trabalho teve como objetivo: Monitorar o fluxo de seiva em 24 plantas adultas de Coffea arabica; Avaliar em função da posição de inserção do sensor na planta (Norte, Sul, Leste ou Oeste) e comparar os resultados com os elementos meteorológicos, como radiação solar, temperatura, umidade relativa e também a evapotranspiração estimada pela equação de Penman-Monteith. O cafezal com 3 anos, localizado em Garanhuns-PE é irrigada por gotejamento. Foram instalados em 24 cafeeiros sensores de dissipação térmica adaptados de Granier (1985), onde o conjunto termopar e resistência foram inseridos na agulha. O ângulo de inserção variou em cada tratamento, foram instalados tensiômetros em diferentes profundidades do solo e medidos a área foliar, o diâmetro do tronco e altura das plantas. O delineamento utilizado foi o inteiramente casualizado com 4 tratamentos e 6 repetições, foi feito teste Tukey a 5% de significância. Com os sensores construídos e instalados nas plantas foi possível determinar a densidade de fluxo de seiva a partir da variação da diferença de temperatura entre as sondas e acompanhar a transpiração em função da transição entre os períodos diurno e noturno. As alturas das plantas variaram entre 1,91 e 2,5 m e área foliar de 3,67 e 12,25 m 2 , máxima e mínima respectivamente. Não houve diferença significativamente entre os ângulos de inserção para o fluxo de seiva. O experimento foi divididos em 3 períodos: antecedente a floração (09/10/07-18/10/07), na floração (22/10/07-01/12/07) e depois da floração (27/12/07-05/01/08) e avaliados quanto a transpiração. Após o período da floração o fluxo foi mais intenso, mas na média sem diferença significativa. Quanto os elementos meteorológicos, a radiação e a umidade relativa foram os fatores mais determinantes da transpiração. pt_BR
dc.description.abstract The increase in productivity with the use of irrigation can be achieved by improved efficiency and accuracy of the use of the technique in the field. Some methods are capable to directly determine the amount of water consumed by a plant, among them, there is the "heat dissipation method" or Granier method. The aim of this study was: Track the sap flow in 24 adult plants of Coffea arabica; Evaluate according to the position of insertion of the sensor in the plant (North, South, East or West) and compared the results with the meteorological elements, such as radiation, temperature, relative humidity and too the evapotranspiration estimated by the Penman-Monteith equation. The coffee plantation with 3 years, located in Garanhuns-PE is drip irrigated. Were installed in 24 coffee sensors, thermal dissipation adapted from Granier (1985), where the set thermocouple and resistance were inserted the needle. The angle of insertion varied in each treatment, were installed tensiometers at different depths of soil and measured the leaf area, the diameter of the trunk and height of crop coffee. The design was used completely randomized to 4 treatments and 6 repetitions, Tukey test was done at 5% significance. With sensors built and installed in the plants were determined the density of sap flow from the variation of the difference in temperature between the probes and monitor the transpiration depending on the transition between day and night periods. The heights of the plants ranged between 1,91 and 2,5 m, leaf area of 3,67 and 12,25 m 2 , maximum and minimum respectively. There was no significant difference between the angles of insertion to the sap flow. The experiment was divided into 3 periods: antecedent to flowering (09/10-18/10), the flowering (22/10- 01/12) and after flowering (27/12-05/01) and evaluated as transpiration. After the period of flowering the flow was more intense, but with no significant difference in the average. As the meteorological elements, radiation and relative humidity were the most determinant factors of transpiration. pt_BR
dc.format 71 folhas pt_BR
dc.language.iso pt_BR pt_BR
dc.publisher Universidade Federal Rural de Pernambuco pt_BR
dc.subject Coffea arabica pt_BR
dc.subject Fluxo de seiva pt_BR
dc.subject Irrigação pt_BR
dc.subject Evapotranspiração pt_BR
dc.subject.classification Cafeicultura::Agroclimatologia e fisiologia pt_BR
dc.title Estimativa da transpiração em cafeeiros utilizando sensores de dissipação térmica pt_BR
dc.title.alternative Estimating of transpiration in crop coffee using heat dissipation sensors pt_BR
dc.type Dissertação pt_BR

Files in this item

Files Size Format View
Dissertacao_Jussalvia da Silva Pimentel.pdf 2.909Mb application/pdf View/Open ou Pre-visualizar

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Sobre o SBICafé

Browse

My Account